Weltek Airkos Main Filter (Weltek Airkos Blower Unit)

£30.00£36.00 Excl. VATIncl. VAT

Dispatch resumes on Monday.
SKU: CR7050 Category: Brand:

Weltek Airkos Main Filter (Weltek Airkos Blower Unit)

Weltek Airkos Main Filter (Weltek Airkos Blower Unit)

Replacement Main Filter (CR-2B01/2013) for Weltek Airkos Blower Unit

Filter should be fully covered by the pre-filter CR7060 and should not exceed 180 hours operational use.

Removing the Filter

Opening the filter cover: Grip the cover on the right hand side and pull the cover open. ATTENTION! It is strictly forbidden to use any tools to open the filter cover.
To remove the filter, pull it off the filter seal while rotating it. Clean the unit from dust. 

Fitting a new Filter

Inserting a new filter: Put the filter back into position using the same rotating motion and gently push until it fits well on the body of the unit. 

Re fitting the Cover; follow the alignment as per the pictures. Ensure the filter clips enter the Blower body, then rotate Clockwise until closed. Do not attempt to use the blower unit without the cover fitted correctly. 

Changing the Pre Filter 

The pre filter is a sleeve which is fitted over the main filter. To remove / replace simply pull off the old filter and stretch the new one into position. It’s important to ensure that the filter media of the main filter is completely covered by the pre filter 